computer-controlled-exhaust-gas-calorimeter
Catalog/Part Number:: TBMC-CG
Description
The Computer Controlled Exhaust Gas Calorimeter, "TBMC-CG", is mounted on a laminated aluminium profiles frame and panels in painted steel.
The main element consists on a double-wall tank made in stainless steel. Through the tank interior the exhaust gases of a combustion engine flow from the lower to the upper part. These gases cross the external surface of a finned steel pipe. Through the pipe interior, crosscurrent water flows with the aim of absorbing the heat contained in the gases which flow through the exterior.
The function of the double-wall is having an air chamber between the gases to be analyzed and the external environment to minimize the heat losses with the exterior.
This Computer Controlled Unit is supplied with the EDIBON Computer Control System (SCADA), and includes: The unit itself + a Control Interface Box + a Data Acquisition Board + Computer Control, Data Acquisition and Data Management Software Packages, for controlling the process and all parameters involved in the process
Technical Specifications
1 TBMC-CG. Unit:
Anodized aluminum frame and panels made of painted steel.
The unit includes wheels to facilitate its mobility.
Main metallic elements made of stainless steel.
Diagram in the front panel with distribution of the elements similar to the real one.
Double-wall tank, made in stainless steel, with a finned steel pipe heat exchanger inside.
Exchange volume: 13 l.
Heat exchange area on exhaust gas side: 1.2 m².
Heat exchange area on water side: 0.17 m².
Exhaust gas inlet at the bottom of the unit.
Exhaust gas outlet at the upper part of the unit
Water inlet and outlet connections and hoses are supplied.
Connection between engine and calorimeter using an exhaust gas a heat-resistant hose.
Regulation valve for the cooling water flow rate.
Four temperature sensors, “J” type, at different process stages, for measurement of:
Exhaust gases temperature at the input.
Gases temperature at the calorimeter output.
Water temperature at the calorimeter input.
Water temperature at the calorimeter output.
Flow sensor to measure the cooling water flow.
Pressure sensor for gases under analysis, range: 0 –1 bar.
Measuring ranges:
Exhaust gas temperature: 0-600 ºC.
Water temperature: 0 – 600 ºC.
Flow rate: 0 – 600 l/hou