ADA5000 Automatic Distillation Analyzer
Catalog/Part Number:: K45604
Description
Test
Method
The sample
is evaporated and condensed under controlled conditions, and observations are
made of the temperatures at which various percentages are recovered and/or the
percentages recovered at specific temperatures.
Features
Conforms to
ASTM D86, D285, D4737 and related international specifications
Pt-100 RTD
probe with automatic temperature calibration system (°C or °F)
Windows®-based
software package for PC control with LIMS export capabilities
Automatic
determination of initial boiling point (IBP), final boiling point (FPB), dry
point and barometric and residue corrections
Diagnostic
system continuously ensures proper unit performance and user safety
Automatic
temperature and volume calibration
Programmable
distillation rate (2-15mL/min)
Ready for
distillation groups 1 - 4
Networking
for up to 32 units
Powerful
CFC-free cooling and heating system
Receiver
chamber heating system up to 60°C
Precision
level follower system with optical meniscus detector
Integrated
automatic fire extinguishing system with manual operation override
Description
The Koehler
Automatic Distillation Analyzer is designed to perform optimal distillation
analyses of gasolines, fuels, oils, solvents, aromatics, napthas, kerosenes,
hydrocarbons, and other volatile products to ensure conformity to rigid quality
control standards. The analyzer automatically performs tests, processes
results, and produces standard reports according to ASTM, ISO, and related
specifications.
Two Models
are Available - The Automatic Distillation Analyzer 5000 Series may be ordered
for operation with an external PC (purchased separately) or may be ordered with
a built-in PC, internal touch screen monitor, virtual keyboard and mouse. An
easy-to-use Windows®-based PC communication software expands user capabilities
for data analysis and unit control. Distillation methods and parameters can be
easily created or modified. Software calculates repeatability and
reproducibility as per ASTM D86 as well as standard and deviation against
reference materials. Test results are displayed in real-time and can include
distillation curve and temperature with or without barometric compensation
and/or evaporation correction, distillation rate, heating power curve, master
curve comparison, and zoom function for high resolution of heating and
temperature curves. The heater compartment is rapidly cooled at the completion
of a distillation run to reduce operator downtime. The analyzers are of rugged
construction for instrument longevity with a modular design for easy routine
maintenance.
Receiver
Chamber Heating System-The receiver chamber heating system is ideal for samples
that form waxes or other solids during distillation.
Dry Point
Detection as Standard Feature - Dry point can be detected visually or by
automatic detection for ASTM D850 and D1078 test methods. The unit is delivered
ready with the PC board components already included as standard to perform the
dry point analysis. Simply order the Automatic Dry Point Detection Kit for Solvents
(see Ordering Information at right) which includes dry point thermocouple,
200mL flask and PTFE plug to perform dry point detection analysis
automatically.
Ready for
Groups 1 - 4 and more - Each Koehler Automatic Distillation Analyzer 5000
Series comes ready with the equipment, accessories and features as standard to
properly run distillation groups 1 to 4 per ASTM D86 and related test
specifications. No additional accessories are required. The Windows®-based
software package allows simple operator selection of the programmed settings
for each distillation protocol. No complicated routines are needed to set up
the unit. User defined programs are easily created for customization of the
analyzer.
Calculated
Cetane Index - Calculated cetane index is a useful tool for estimating ASTM
D4737 cetane number where a test engine is not available for determining this
properly. It may be conveniently employed for approximating cetane number where
the quantity of sample is too small for an engine rating. In cases where the
cetane number of a fuel has been initially established, the index is useful as
a cetane number check on subsequent samples of that fuel, provided its source
and mode of manufacture remain unchanged. The Cetane index is automatically
calculated at the end of the test if all the necessary variables are entered
and is a component of the Windows®- based software which comes standard with
the unit.
Carbon Residue on 10% Distillation Residue - As per section 10, ASTM D189 the procedure for carbon residue of light distillate oils can be performed.
Included
Accessories
Distillation
Flask, 125mL with Markings
Ceran Plate,
25mm dia. hole
Ceran Plate,
38mm dia. hole
Ceran Plate,
50mm dia. hole
3 Point
Calibrated PT100 Thermometer with Cable and Plug
Special
Graduated Receiver Cylinder with Base
Wiper for
Condenser Tube
Dropping
Plate
Teflon Plug
for 125mL Flask
Silicone
Plug for Flask Side Arm
Dry Point
Detection Board
Windows®-based
Automatic Distillation Software
Technical Specifications
Specifications
Conforms to
the specifications of: ASTM D86, D285, D850, D1078, D4737; D189 Section 10; DIN
51751; ISO 3405; IP 123; IP 195; JIS K0066; JIS K2254; NF M 07-002
Temperature
Distillation Range: 0 to 450°C (±0.1°C accuracy)
Condenser:
-5 to 60°C (±0.1°C accuracy); closed loop system
Receiver
Chamber: 0 to 60°C (±0.1°C accuracy)
Distillation
Parameters:
Distillation
Rate: 2 to 15mL/min in 0.1mL increments, user selectable
Receiver
Volume: 0 to 100mL (±0.01mL accuracy) by photoelectric infrared detection of
meniscus by level following system utilizing a precision stepper motor and a
special calibrated glass receiver; automatic calibration of evaporated loss
volume and automatic volume calibration system ensures highest accuracy
Barometic
Pressure: Automatic barometric correction utility with automatic sensor, range
550 to 900 mm Hg (±1 mm Hg accuracy)
Dry Point
Detection: Automatic dry point detection board is included with standard
equipment and only requires a dry point sensor, 200mL flask and PTFE plug for
ASTM D850 and D1078 tests.
Environment:
Operates at 0 to 25°C (113°F)
Electrical
Requirements
100-240V /
50-60Hz
Output:
15V/40 VA
Dimensions
lxwxh,in.(cm):
21x21.5x27.75 (53.3x54.6x70.5)
Additional
Accessories
K45634
Distillation Flask, 125mL with Markings
K45635 PTFE
Centering Stopper for 125mL Flask
K45655 Ceran
Plate, 32mm dia. hole
K45656 Ceran
Plate, 38mm dia. hole
K45657 Ceran
Plate, 50mm dia. hole
K45656-A
Ceran Plate, 25mm dia. hole
K45650 PT100
Thermometer with Cable and Plug
K45651-E
Special Graduated Receiver Cylinder (with base)
K45651-B
Special Graduated Receiver Cylinder (without base)
K45601-03014
Condenser Tube Cleaning Assembly
K45668
Dropping Plate
K45654-A
Flask 200mL with Silicon Plu
K45652-C
Silicone Plug
K45654
Automatic Dry Point Detection Kit for D850 and D1078
Zero(0) Reviews